Reinforcement detailing free download as powerpoint presentation. Design manual to bs8110 linkstud psr limited co brooks forgings ltd. Minimum horizontal reinforcement in rc walls ec2 structural. Autocad structural detailing software, built on the familiar autocad platform, helps structural engineers, detailers, and fabricators to create more precise detailing and fabrication shop drawings. Extract from how to design concrete structure using eurocode 2. If you require any further detailed advice regarding the design and detailing of punching shear reinforcement to either the ec2 or bs8110 standards. For slender walls where the bending deformation is more, shear wall resists the loads due to. The design and detailing requirements for special reinforced concrete shear walls have undergone significant changes from aci 31811 to aci 31814. The first reinforced concrete design manual formerly titled aci design handbook was developed in accordance with the design provisions of 1963 aci 318 building code by aci committee 340, design. Designing these fi ve coupling beams without diagonal reinforcement, using horizontal. There are detailed rules for punching shear reinforcement.
Reinforced wall with prescriptive reinforcement of detailed plain shear wall. Reinforcement detailing appendix a to this section. Specialists in punching shear reinforcement linkstudpsr design manual to bs8110 linkstud psr limited co brooks forgings ltd doulton road cradley heath west midlands b64 5qj tel. Pdf design and construction of shear walls levi edwig. See more ideas about shearing, wall and civil engineering. The first choice is to use slack in the bar laps to accommodate a variety of heights. The clauses and values for most detailing minima and maxima are given in table 1 below.
Reinforced concrete shear wall analysis and design a structural reinforced concrete shear wall in a 5story building provides lateral and gravity load resistance for the applied load as shown in the figure below. Shear wall section and assumed reinforcement is investigated after analysis to verify suitability for the applied loads. Ugc approved journal,ugc approved journal,ugc and issn approved,ugc approved, ugc,ugc, ugc approved journal, ugc approved journal,issue,paper,research,journal,ijirt,international,volume,author,publication,scopus approved journal, scopus, scopus indexed journal, scopus journal, free publication, publish free, free of. Manual for design and detailing of reinforced concrete to the code.
For a bar adjacent to the face of the member, ab should be taken as. Detailing of reinforcement a2 14n16s300ef information for placing with clause 23. For slender walls where the bending deformation is. Nov 02, 2017 shear wall is a structural member used to resist lateral forces i. Shear wall is a structural member used to resist lateral forces i. Ductile flexural walls required to have concentrated vertical reinforcement near each end of the wall designed for the combined actions of gravity load and. Manual for design and detailings of reinforced concrete to. The remainder of this section describes in detail the design process used by the.
This manual deals exclusively with the correct use of the now withdrawn bs8110. This ig insider pssible effect 1,23 124 is, shar reinforcement be with ard 1. Bar shape code bar number in sequence number of bars in the set bar size in millimetres bar mark 4. The detailing requirements of a reinforcement bar depend on the reasons for its inclusion in. Shear wall design for a building in seismic zone iii 69. The primary shear wall element of a compound shear wall was designed considering an effective flange width of 12, which becomes the minimum boundary zone length that extends into the web of the secondary shear wall element figure 2.
The mat depth is normally set by shear strength requirements. A letter should prefix the bar sequence number to w for round reinforcing. Active earth pressure tends to variation of earth pressure deflect the wall away from the 5 backfill. Foreword the reinforced concrete design manual sp1711 is intended to provide guidance and assistance to professionals engaged in the design of castinplace reinforced concrete structures. During this lesson you will learn the basics of seismic design of reinforced concrete buildings. Design and detailing of retaining walls learning outcomes.
When detailing substructures, it is preferable not to use series bars unless necessary. Each detailed change usually has some merit, but taken together the small changes may discourage the use of concrete shear walls. The amount of reinforcement a s for the top and bottom reinforcing layers is set by meeting aci 318 code1 requirements for flexural strength, minimum flexural reinforcement sections 10. This analysis ensured a primary shear wall boundary zone length based on the 0. As to the minimum crosssectional area of transverse reinforcement, there is no difference now between an smf column hinging region and the specially confined boundary zone of a special shear wall. Manual for design and detailing of reinforced concrete to the september 20 code of practice for structural use of concrete 20 2. Manual for the design of reinforced concrete building. The first choice is to use slack in the bar laps to accommodate a. Shear wall detailing structural engineering general.
Manual for design and detailing of reinforced concrete to. Detailing of reinforcement in concrete structures engineers. Design example 2 n reinforced concrete wall with coupling beams outline 1. According to the standard ec2, it states that the minimum horizontal reinforcement of a wall to be greater of 25% of vertical reinforcement or 0. Design for shear in reinforced concrete using strutand. Faster and more efficient reinforcement detailing and scheduling. Maximum design shear stresses of concrete vmax are raised. Department of transportation bar reinforcement details. Cantilever retaining wall with shear keywith shear key batter drainage hole toe 2. In general, the wall reinforcement consists of two layers of distributed reinforcefigure 2. Generally, greater lengths of perforated shear walls are needed to resist lateral loads than segmented shear walls. Placing a shear cage of welded wire reinforcement in a concrete girder for a sports stadium.
Maximum area of compression reinforcing steel in a wall pier edge member, mm2. Pdf manual for design and detailing of reinforced concrete to. Details and detailing of concrete reinforcement ac1599 manual of structural and placing drawings for reinforced concrete structuresac15r04 supporting reference data ac1committee315 detailsofconcretereinforcement ronald d. Reinforced concrete shear wall foundation strip footing analysis and design a 12 in. Spacing of vertical reinforcement reduced to 48 inches. Manual for design and detailing of reinforced concrete to september 20 the code of practice for structural use of concrete 20 contents 1. Explanatory examples for ductile detailing of rc buildings. Nominal shear stress, shear strength of walls 10 v u v w w v t d factored shear force thickness of wall section effective depth of wall section for rectangular sections 0. Rta structural drafting steel reinforcement detailing and detailing manual otb005 issue 1 revision 2 05 march 2010 page 3 of 3 the lap splice length of bars in tension shall be not less than the development length, lsy. Good detailing ensures that reinforcement and concrete interact efficientlyto provide satisfactory behaviour throughout the complete range of loading. Reinforced concrete shear wall foundation strip footing. Seismic design of reinforced concrete structures topic 11 is the seismic design of reinforced concrete structures, primarily buildings. The information presented covers the seismic design and detailing requirements for all concrete masonry construction with the exception of concrete masonry veneers, which is addressed in tek 36b, concrete masonry veneers ref.
Ec2 webinar autumn 2017 lecture 93 minimum mandrel size. This manual provides wwr product information, material specifications, design and detailing requirements, and various tables and design aids for those interested in the design and construction of reinforced concrete structures. Reinforced concrete shear wall analysis and design structurepoint. Shear walls are one of the excellent means for providing earthquake resistance to multistoreyed reinforced concrete. They are briefly repeated as follows for ease of reference. Concrete shear wall construction 3 shear wall buildings in romania whe report 78 have lightly reinforced walls, with one layer of 2mmdiameter vertical bars and 8mm horizontal bars. May 10, 2018 both the design for overturning and the design for shear are explained. The requirements listed below for each sdc and shear wall type are cumulative. To license autocad structural detailing software, contact an autodesk premier solutions provider or autodesk authorized reseller. Design of concrete shear wall spandrels for flexure. Coupling beam strength and diagonal reinforcement 5.
Reinforcement pdf vol iv detailing bridge planning and design manual dumber. Reinforcement requirements are based on building code requirements specific for each country. Provisions are also given for detailing of reinforcement in the wall web, boundary elements, coupling beams, around openings, at construction joints, and for. In the final series, the effects of load distribution on specimens without shear reinforcement were observed. Feb 10, 2015 nominal shear stress, shear strength of walls 10 v u v w w v t d factored shear force thickness of wall section effective depth of wall section for rectangular sections 0.
This gl pressure tends to deflect the wall outward. The institution of structural engineers the institution of civil engineers march 2000 manual for the design of reinforced concrete building structures to ec2. Manual for design and detailings of reinforced concrete to code of practice for structural use of concrete 2004 housing department. He was managing director of engineering for the american concrete institute from 1998 until his. For the design of shear walls with openings, the designer has the option of using the segmented, perforated, or force transfer around openings classifications. Shear wall or lift core design in etabs 2016 in details youtube. I have attached the detailing manual code for the reference for this clause published by istruct.
The sectionaldesign model is appropriate for the design of a. The following changes have been made in the nonspecial confinement requirements of section 18. Structure magazine special reinforced concrete shear walls. Buildings designed using these principles will fare better in a seismic event than the building shown in this slide.
Design example 2 reinforced concrete wall with coupling. Detailing page 94, figure 10 punching shear reinforcement. Falconer and his many contributions to the concrete industry. Wall loading, moment and deflection diagramswind and axial load moments not additive. To make distinctions between the equations quoted from the code and the equations derived in this manual, the former will be prefixed by ceqn and the latter by eqn. The reinforced concrete design handbook provides assistance to professionals engaged in the design of reinforced concrete buildings and related structures. Detailing lecture 9 16 th november 2017 reinforced concrete detailing to eurocode 2 ec2 section 8 detailing of reinforcement general rules bar spacing, minimum bend diameter anchorage of reinforcement lapping of bars large bars, bundled bars ec2 section 9 detailing of members and particular rules beams solid slabs flat slabs columns walls. Details and detailing of concrete reinforcement aci 31599 reported by aci committee 315 aci 31599 ronald d. Topic 11 seismic design of reinforced concrete structures. P a active earth pressure or earth pressure pa and passive earth pressure pp. Ugc approved journal,ugc approved journal,ugc and issn approved,ugc approved, ugc,ugc, ugc approved journal, ugc approved journal,issue,paper,research,journal,ijirt,international,volume,author,publication,scopus approved journal, scopus, scopus indexed journal, scopus journal, free publication, publish free, free of cost publication, free,internationaljouranl,journal,research,research paper. Dedication this edition of the reinforced concrete design handbook, sp1714, is dedicated to the memory of daniel w. Manual for design and detailing of reinforced concrete to the.
The reinforcement spacing varies from 50 mm to 250 mm for walls in the longitudinal and transverse direction, respectively. Wall loading, moment and deflection diagramswind and axial load moments additive. Identify and understand the basic shear wall system to resist lateral loads understand the difference between segmented and perforated shear wall design understand hold down design identify and analyze shear walls per the ibc, wfcm, and sdpws and understand the differences between them 4 polling question 1. The shear wall carries service dead and live loads of 10 kipsft and 12.
Autocad structural detailing helps improve design accuracy by providing tools that automate the generation of more complete and comprehensive. Shear walls 2 reinforcement not required at openings smaller than 16 in. Design of concrete shear walls fprimec solutions inc. The remainder of this section describes in detail the design process used by the program for. The effects of beam width and shear spantodepth ratio on shear strength were studied using the second series of beam tests. Detailing of special shear walls rather than focusing on changes in details, step back and look at the system design approach in general. Design example 2 reinforced concrete wall with coupling beams. The first reinforced concrete design manual formerly titled aci design handbook was developed in accordance with the design provisions of 1963 aci 318 building code by aci. An aci handbook the reinforced concrete design handbook. In this seminar, guidelines for successful detailing in structural elements and connections are outlined. The prescriptive seismic detailing requirements for each of three reinforced masonry shear walls types, ordinary, intermediate, and special, are explained, with particular attention to special reinforced shear walls.
159 305 271 509 230 481 602 107 637 1018 504 1645 617 785 316 740 780 279 861 330 35 1653 322 1656 627 515 1137 106 1296 296 830 225 1135 1298 1453 240 1329 1050 1382 461